Line 5: Line 5:
 
|-
 
|-
 
| '''Beam Kinetic Energy, T (MeV)'''
 
| '''Beam Kinetic Energy, T (MeV)'''
|  3.0 – '''7.75'''  
+
|  3.0 – '''9.0'''  
 
|-
 
|-
 
| '''Beam Current (µA)'''
 
| '''Beam Current (µA)'''
Line 17: Line 17:
 
|-
 
|-
 
| '''Energy Resolution (Spread), σ<sub>T</sub> /T'''
 
| '''Energy Resolution (Spread), σ<sub>T</sub> /T'''
|  0.06%  
+
|  0.2%  
 
|-
 
|-
 
| '''Beam Size, σ<sub>x,y</sub> (mm)'''
 
| '''Beam Size, σ<sub>x,y</sub> (mm)'''
Line 23: Line 23:
 
|}
 
|}
  
  Goals:
+
  Goal:
  - Increase beam kinetic energy to '''8.5 MeV'''.
 
 
   - Reduce the uncertainty on the absolute beam energy to '''<0.1%''' and achieve a relative beam energy of '''<0.02%'''.
 
   - Reduce the uncertainty on the absolute beam energy to '''<0.1%''' and achieve a relative beam energy of '''<0.02%'''.
  

Latest revision as of 07:52, 13 April 2018

Summary of Beam Properties in JLab Injector

Beam Kinetic Energy, T (MeV) 3.0 – 9.0
Beam Current (µA) 0.01 – 100
Absolute Beam Energy 0.36%
Relative Beam Energy 0.1%
Energy Resolution (Spread), σT /T 0.2%
Beam Size, σx,y (mm) 1 – 2
Goal:
 - Reduce the uncertainty on the absolute beam energy to <0.1% and achieve a relative beam energy of <0.02%.


Mott Results


Dipole Field


New Dipole Magnet

  1. Magnet Design: media:new_5MeV_dipole.pdf media:new_5MeV_dipole.doc
  2. Magnet Drawings (change txt to tar): media:05-06-14_ISSUED_DL_MAG_DRAWINGS.txt
  3. A detailed examination of the MDL field map and the TOSCA model of this "5 MeV" dipole

Jay Benesch (JLab Tech note 15-017, September 9, 2015): media:TN-15-017_MDL_FieldMap.pdf media:Graphs_MDL.pdf media:Graphs_MDL.docx


New Hall Probe

  1. GMW DTM-151-PS Digital Teslameter, 20 Bit Resolution, RS-232 Interface, Panel Mtg media:G3_MAN_DTM-151-S.pdf
  2. GMW MPT-231-8s Miniature Hall Probe with thermal sensor, High Sensitivity 0.03T, 0.06T, 0.12T, & 0.3T, 8m shielded cable. 0.01% accuracy, resolution to 2 ppm, and a temperature stability of 10 ppm/°C.


PEPPo Results

Momentum Measurement:

Cryounit Gradient:

  • Upper limit of the electron beam energy at the CEBAF 2D injector spectrometer and its functionality

Jonathan Dumas, Joe Grames, and Eric Voutier Media:JLAB-TN-08-086.pdf