Difference between revisions of "Designs"

From Ciswikidb
Jump to navigation Jump to search
 
(7 intermediate revisions by one other user not shown)
Line 9: Line 9:
 
** Cathode electrode one-piece body: ACC-200-3000-0301  [[Media:Tee electrode manufacturing drawing.pdf]]
 
** Cathode electrode one-piece body: ACC-200-3000-0301  [[Media:Tee electrode manufacturing drawing.pdf]]
  
* 18" Chamber: [[media:LeskerPrint.pdf]]
+
* 18" Chamber:  
 +
** Lesker prints
 +
*** [[media:LeskerPrint.pdf]]
 +
*** [[media:leskerprint2.pdf]]
 +
*** [[media:leskerprint3.pdf]]
 +
*** [[media:leskerprint4.pdf]]
 +
*** [[media:leskerprint5.pdf]]
 +
 
 
** Spherical electrode: ACC-200-3000-0440
 
** Spherical electrode: ACC-200-3000-0440
 
** 18" chamber JLab dwg: ACC-200-3000-0449
 
** 18" chamber JLab dwg: ACC-200-3000-0449
Line 32: Line 39:
 
** macor bushing: ACC-200-3000-0348
 
** macor bushing: ACC-200-3000-0348
 
** steel pipe standoff: ACC-200-3000-0601
 
** steel pipe standoff: ACC-200-3000-0601
 +
* 45 degree bend tube for ion pump: [[media:45Elbow.pdf]]
  
 
== Prep chamber ==
 
== Prep chamber ==
Line 57: Line 65:
 
* Y chamber injector: Kurt J Lesker PRD180090-0500
 
* Y chamber injector: Kurt J Lesker PRD180090-0500
  
== Wien filters ==
+
==Wien filters==
 +
The CEBAF injector counts with a Vertical and a Horizontal Wien filter. The document describes the system and guidelines for operations, but it DOES NOT describe SAFETY LOTO procedures. This will have to be covered in a specific OSP.
 +
* [[File:CEBAF Wien filters HV system operational guidelines updated April 11 2022.pdf|right|middle|thumb]]
  
 +
== Interlocks ==
 +
* UHV interlock chain [[media:UHVInterlock.pdf]]
 +
* CEBAF vacuum interlock chain [[media:CebafInjInterlocks.pdf]]
  
 
== Magnets ==
 
== Magnets ==

Latest revision as of 10:18, 12 June 2023

Drawings and Designs

See also Carlos Gun drawings page: https://wiki.jlab.org/ciswiki/index.php/Gun_assemblies,_electrostatic_models_and_field_maps

Gun Designs

    • Spherical electrode: ACC-200-3000-0440
    • 18" chamber JLab dwg: ACC-200-3000-0449
    • Front flange: ACC-200-3000-0451
    • Spherical electrode shell: ACC-200-3000-0460
    • Electrode front end: ACC-200-3000-0461
    • "HV Stalk Flange"? Insulator flange?: ACC-200-3000-0465
    • Electrode key: ACC-200-3000-0466
    • Spherical electrode: Internal mount: ACC-200-3000-0467
    • HV Chamber ring holder - connection to insulator?: ACC-200-3000-0468
    • Spring holder (puck dock in electrode): ACC-200-3000-0469
    • Electrode Back end: ACC-200-3000-0607
  • Anode standoff parts
    • 3.680" long, 3 holes: 32709-C-0454
    • 3.430" long, 3 holes: ACC-200-3000-0213
    • 1.170" long, 3 holes: ACC-200-3000-0349
    • 1.429" long, 3 holes: ACC-200-3000-0344
    • Proud anode: ACC-200-3000-0345
    • Bore shield 0.5": ACC-200-3000-0346
    • macor spacer: ACC-200-3000-0347
    • macor bushing: ACC-200-3000-0348
    • steel pipe standoff: ACC-200-3000-0601
  • 45 degree bend tube for ion pump: media:45Elbow.pdf

Prep chamber

  • Bottom flange: ACC-200-3000-0151
  • Prep body: ACC-200-3000-0130
    • ring anode: ACC-200-3000-0139
    • Puck pin: ACC-200-3000-0317
    • Suitcase manip end: ACC-200-3000-0170



Gun Table

  • Table top: ACC-200-3000-0171
  • Gun table assy: ACC-200-3000-0190


Loading Chamber

Y chamber(s)

  • Laser table girder assembly JL0091130-0201
  • Y chamber injector: Kurt J Lesker PRD180090-0500

Wien filters

The CEBAF injector counts with a Vertical and a Horizontal Wien filter. The document describes the system and guidelines for operations, but it DOES NOT describe SAFETY LOTO procedures. This will have to be covered in a specific OSP.

Interlocks

Magnets

  • FG magnet top assy: MAG-009-0040-0001


DP cans

harp

  • Super harp assy (12GeV harp): DIA-007-0200-3001
    • Horizontal assy: DIA-007-0200-3025
    • 12 GeV harp fork: DIA-007-0200-3039
    • another 12 GeV Harp fork: DIA-007-0200-3028
    • Harp flange: DIA-007-0200-3008
    • Harp BNC connector weldment: DIA-007-0200-3009


viewers