Difference between revisions of "2018 Mott Paper Working Area"

From Ciswikidb
Jump to navigation Jump to search
Line 5: Line 5:
  
 
*Run 1  
 
*Run 1  
::Online Analysis Spreadsheet : [[media:run1database.ods]] -- ''''Spreadsheet compiled while gathering data during Run I. Can be used as look-up table to determine which runs were used for which study. Asymmetry and rate numbers contained within are from preliminary analysis that does not include cuts, background handling etc. and so should not be referenced as final numbers.''''
+
::*Online Analysis Spreadsheet : [[media:run1database.ods]] -- ''''Spreadsheet compiled while gathering data during Run I. Can be used as look-up table to determine which runs were used for which study. Asymmetry and rate numbers contained within are from preliminary analysis that does not include cuts, background handling etc. and so should not be referenced as final numbers.''''
::Asymmetry vs Foil Thickness Full Analysis Spreadsheet : [[media:06.01.17_Run1_ARC+Dilution.ods]] -- ''''Final analysis numbers contained within, to be used and referenced in paper.''''
+
::*Asymmetry vs Foil Thickness Full Analysis Spreadsheet : [[media:06.01.17_Run1_ARC+Dilution.ods]] -- ''''Final analysis numbers contained within, to be used and referenced in paper.''''
  
 
*Run 2  
 
*Run 2  
::Online Analysis Spreadsheet : [[Media:Run2RawData.ods]] -- ''''Spreadsheet compiled while gathering data. Can be used as look-up table to determine which runs were used for which study. Asymmetry and rate numbers contained within are from preliminary analysis that does not include cuts, background handling etc. and so should not be referenced as final numbers.''''
+
::*Online Analysis Spreadsheet : [[Media:Run2RawData.ods]] -- ''''Spreadsheet compiled while gathering data. Can be used as look-up table to determine which runs were used for which study. Asymmetry and rate numbers contained within are from preliminary analysis that does not include cuts, background handling etc. and so should not be referenced as final numbers.''''
::Asymmetry vs Foil Thickness Full Analysis Spreadsheet : [[media:06.01.17_Run2_ARC+Dilution.ods]] -- ''''Final analysis numbers contained within, to be used and referenced in paper.''''
+
::*Asymmetry vs Foil Thickness Full Analysis Spreadsheet : [[media:06.01.17_Run2_ARC+Dilution.ods]] -- ''''Final analysis numbers contained within, to be used and referenced in paper.''''
  
 
*[[Data Analysis Working Area]]
 
*[[Data Analysis Working Area]]

Revision as of 13:20, 8 November 2018

General Links/Documents

  • Run 1
  • Online Analysis Spreadsheet : media:run1database.ods -- 'Spreadsheet compiled while gathering data during Run I. Can be used as look-up table to determine which runs were used for which study. Asymmetry and rate numbers contained within are from preliminary analysis that does not include cuts, background handling etc. and so should not be referenced as final numbers.'
  • Asymmetry vs Foil Thickness Full Analysis Spreadsheet : media:06.01.17_Run1_ARC+Dilution.ods -- 'Final analysis numbers contained within, to be used and referenced in paper.'
  • Run 2
  • Online Analysis Spreadsheet : Media:Run2RawData.ods -- 'Spreadsheet compiled while gathering data. Can be used as look-up table to determine which runs were used for which study. Asymmetry and rate numbers contained within are from preliminary analysis that does not include cuts, background handling etc. and so should not be referenced as final numbers.'
  • Asymmetry vs Foil Thickness Full Analysis Spreadsheet : media:06.01.17_Run2_ARC+Dilution.ods -- 'Final analysis numbers contained within, to be used and referenced in paper.'

Draft Punchlist

Request #1 -- Ready for Review

We measured dependence of electronic dead time on the beam current at five different average beam currents from 0.245-4.1 uA on a 1um foil. He'd like a plot showing the five data points vs. beam current with their individual uncertainties, and then the average with it's uncertainty band.

ROOT deadtime asym v beamcurrent.gif
media:Deadtime vs beamcurrent.ods
Avg deadtime v beamcurrent.gif

Request #2 -- Ready for Review

We measured dependence of the physics asymmetry on the position of the beam on the target foil from two target foils: 0.225um and 1um. For each foil we measured 7 asymmetries (one at center and six others away from center). The details are described in the systematics TN on the wiki. He'd like a plot showing the measured physics asymmetries (weighted average of IN/OUT) vs. radial distance from the center (instead of using x/y values shown in the TN), and then the average with it's uncertainty band, for the two target foils.

Asym v beampos 1000.gif
Asym v beampos 225.gif
media:Asym v beampos final.ods

Request #3 -- Ready for Review

Recreate Michael's Paper's Plot: Remaking of Figure 6: media:Au_targetMSteigerwald.gif. The lines are a fit ( asym = a / (1.0 + alpha . d) ). On the original figure, the lines were his calculations.

Au targetMSteigerwald.gif

Request #4 -- Info Provided

We need an imagine of a typical FESEM picture showing a gold foil on a silicon substrate, or maybe 2 or 4 of them arranged to show typical measured you used in the analysis.

=> Here are some examples of foil thickness, which set of foils would be interesting to use? => Media:foil_Thickness_status-5June2015B.pptx

Request #5 -- Info Provided

For two foils, two samples were prepared – one near the foil center and one near the edge, and each were measured. Where are those results (or FESEM images) ?

=> Here is the summary of the measurements where two foils have "edge" and "center" values, is this sufficient ? Media:Summary_all_foils_5June2015C.xlsx

Request #6 -- Ready for Review

The detectors are centered at theta=172.6. We should check if S is maximum there or not. => The answer is that the maximum for KE=5MeV Au is 173.1 per Xavier and 129.9 per Ketevi. I think we erred perhaps so that the solid angle intercepted S at the same value left/right, or something like that.